10 20 30 40 50
MSGIALSRLA QERKAWRKDH PFGFVAVPTK NPDGTMNLMN WECAIPGKKG
60 70 80 90 100
TPWEGGLFKL RMLFKDDYPS SPPKCKFEPP LFHPNVYPSG TVCLSILEED
110 120 130 140 150
KDWRPAITIK QILLGIQELL NEPNIQDPAQ AEAYTIYCQN RVEYEKRVRA
158
QAKKFAPS

Data source: UniProt


Position of Targeted Peptide Analytes Relative to SNPs, Isoforms, and PTMs

Uniprot Database Entry PhosphoSitePlus ®

Click a point on a node
to view detailed assay information below
All other points link out to UniProt



Phosphorylation Acetylation Ubiquitylation Other

loading

Loader

Assay Details for CPTAC-1469 Collapse assay details

Data source: Panorama

Official Gene Symbol
UBE2I
Peptide Sequence
DDYPSSPPK
Modification Type
unmodified
Protein - Site of Modification
N/A
Peptide - Site of Modification
N/A
Peptide Start
66
Peptide End
74
CPTAC ID
CPTAC-1469
Peptide Molecular Mass
1,004.4451
Species
Homo sapiens (Human)
Assay Type
Direct ImmunoMRM
Matrix
depleted digested plasma
Submitting Laboratory
Broad Institute
Submitting Lab PI
Steven A. Carr

Publication

View Details (opens in a new window)

Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma. Abbatiello SE, Schilling B, Mani DR, Zimmerman LJ, Hall SC, MacLean B, Albertolle M, Allen S, Burgess M, Cusack MP, Gosh M, Hedrick V, Held JM, Inerowicz HD, Jackson A, Keshishian H, Kinsinger CR, Lyssand J, Makowski L, Mesri M, Rodriguez H, Rudnick P, Sadowski P, Sedransk N, Shaddox K, Skates SJ, Kuhn E, Smith D, Whiteaker JR, Whitwell C, Zhang S, Borchers CH, Fisher SJ, Gibson BW, Liebler DC, MacCoss MJ, Neubert TA, Paulovich AG, Regnier FE, Tempst P, Carr SA. Mol Cell Proteomics. 2015 Sep;14(9):2357-74. doi: 10.1074/mcp.M114.047050. Epub 2015 Feb 18. PMID: 25693799


Assay Parameters Collapse assay parameters

Data source: Panorama

Instrument
Quantiva TSQ
Internal Standard
heavy stable isotope peptide (delta 8-10)
Peptide Standard Purity
>95%
Peptide Standard Label Type
15N
LC
Easy NanoLC1000
Column Packing
Reprosil C18, 1.9um, 200A
Column Dimensions
0.075 x 150 mm
Flow Rate
200 nL/min

Chromatograms

Data source: Panorama


Response Curves

Data source: Panorama

Retrieving Data

Loader

Repeatability

Data source: Panorama

  Average intra-assay CV
(within day CV)
Average inter-assay CV
(between day CV)
Total CV
equation
n=
Fragment ion / Transition Low Med High Low Med High Low Med High Low Med High
y7 (1+) 4.2 2.5 1.3 7.2 6.8 3.5 8.3 7.2 3.7 15 15 15
y5 (1+) 4.4 2.4 1.7 5.7 6.7 3.3 7.2 7.1 3.7 15 15 15
y6 (1+) 2.2 1.5 0.9 3.9 5.9 3.2 4.5 6.1 3.3 15 15 15
sum 2.1 1.4 0.8 4 6 3.1 4.5 6.2 3.2 15 15 15


Additional Resources and Comments


Assay Details for CPTAC-1471 Collapse assay details

Data source: Panorama

Official Gene Symbol
UBE2I
Peptide Sequence
DHPFGFVAVPTK
Modification Type
unmodified
Protein - Site of Modification
N/A
Peptide - Site of Modification
N/A
Peptide Start
19
Peptide End
30
CPTAC ID
CPTAC-1471
Peptide Molecular Mass
1,313.6768
Species
Homo sapiens (Human)
Assay Type
Direct ImmunoMRM
Matrix
depleted digested plasma
Submitting Laboratory
Broad Institute
Submitting Lab PI
Steven A. Carr

Publication

View Details (opens in a new window)

Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma. Abbatiello SE, Schilling B, Mani DR, Zimmerman LJ, Hall SC, MacLean B, Albertolle M, Allen S, Burgess M, Cusack MP, Gosh M, Hedrick V, Held JM, Inerowicz HD, Jackson A, Keshishian H, Kinsinger CR, Lyssand J, Makowski L, Mesri M, Rodriguez H, Rudnick P, Sadowski P, Sedransk N, Shaddox K, Skates SJ, Kuhn E, Smith D, Whiteaker JR, Whitwell C, Zhang S, Borchers CH, Fisher SJ, Gibson BW, Liebler DC, MacCoss MJ, Neubert TA, Paulovich AG, Regnier FE, Tempst P, Carr SA. Mol Cell Proteomics. 2015 Sep;14(9):2357-74. doi: 10.1074/mcp.M114.047050. Epub 2015 Feb 18. PMID: 25693799


Assay Parameters Collapse assay parameters

Data source: Panorama

Instrument
Quantiva TSQ
Internal Standard
heavy stable isotope peptide (delta 8-10)
Peptide Standard Purity
>95%
Peptide Standard Label Type
13C and 15N at C-terminus K
LC
Easy NanoLC1000
Column Packing
Reprosil C18, 1.9um, 200A
Column Dimensions
0.075 x 150 mm
Flow Rate
200 nL/min

Chromatograms

Data source: Panorama


Response Curves

Data source: Panorama

Retrieving Data

Loader

Repeatability

Data source: Panorama

  Average intra-assay CV
(within day CV)
Average inter-assay CV
(between day CV)
Total CV
equation
n=
Fragment ion / Transition Low Med High Low Med High Low Med High Low Med High
y5 (1+) 4.9 3.6 2.7 6.2 6.9 2.9 7.9 7.8 4 15 15 15
y4 (1+) 7.3 2.6 3.9 6.3 6.4 4.1 9.6 6.9 5.7 15 15 15
y6 (1+) 12.1 4.9 3.9 17.4 7 3.6 21.2 8.5 5.3 15 15 15
sum 5 2.7 2.3 6.6 6.6 2.8 8.3 7.1 3.6 15 15 15


Additional Resources and Comments


Assay Details for CPTAC-1470 Collapse assay details

Data source: Panorama

Official Gene Symbol
UBE2I
Peptide Sequence
DWRPAITIK
Modification Type
unmodified
Protein - Site of Modification
N/A
Peptide - Site of Modification
N/A
Peptide Start
102
Peptide End
110
CPTAC ID
CPTAC-1470
Peptide Molecular Mass
1,098.6186
Species
Homo sapiens (Human)
Assay Type
Direct ImmunoMRM
Matrix
depleted digested plasma
Submitting Laboratory
Broad Institute
Submitting Lab PI
Steven A. Carr

Publication

View Details (opens in a new window)

Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma. Abbatiello SE, Schilling B, Mani DR, Zimmerman LJ, Hall SC, MacLean B, Albertolle M, Allen S, Burgess M, Cusack MP, Gosh M, Hedrick V, Held JM, Inerowicz HD, Jackson A, Keshishian H, Kinsinger CR, Lyssand J, Makowski L, Mesri M, Rodriguez H, Rudnick P, Sadowski P, Sedransk N, Shaddox K, Skates SJ, Kuhn E, Smith D, Whiteaker JR, Whitwell C, Zhang S, Borchers CH, Fisher SJ, Gibson BW, Liebler DC, MacCoss MJ, Neubert TA, Paulovich AG, Regnier FE, Tempst P, Carr SA. Mol Cell Proteomics. 2015 Sep;14(9):2357-74. doi: 10.1074/mcp.M114.047050. Epub 2015 Feb 18. PMID: 25693799


Assay Parameters Collapse assay parameters

Data source: Panorama

Instrument
Quantiva TSQ
Internal Standard
heavy stable isotope peptide (delta 8-10)
Peptide Standard Purity
>95%
Peptide Standard Label Type
15N
LC
Easy NanoLC1000
Column Packing
Reprosil C18, 1.9um, 200A
Column Dimensions
0.075 x 150 mm
Flow Rate
200 nL/min

Chromatograms

Data source: Panorama


Response Curves

Data source: Panorama

Retrieving Data

Loader

Repeatability

Data source: Panorama

  Average intra-assay CV
(within day CV)
Average inter-assay CV
(between day CV)
Total CV
equation
n=
Fragment ion / Transition Low Med High Low Med High Low Med High Low Med High
y6 (2+) 9.1 6.1 3.2 8.4 8.6 3 12.4 10.5 4.4 15 15 15
y8 (2+) 9.6 5.9 3.7 10 8 4.9 13.9 9.9 6.1 15 15 15
y7 (2+) 4.7 3.8 2.3 6.1 7.2 3.6 7.7 8.1 4.3 15 15 15
sum 3.5 3 1.9 5.1 6.8 3.3 6.2 7.4 3.8 15 15 15


Additional Resources and Comments


Assay Details for CPTAC-711 Collapse assay details

Data source: Panorama

Official Gene Symbol
UBE2I
Peptide Sequence
DHPFGFVAVPTK
Modification Type
unmodified
Protein - Site of Modification
N/A
Peptide - Site of Modification
N/A
Peptide Start
19
Peptide End
30
CPTAC ID
CPTAC-711
Peptide Molecular Mass
1,313.6768
Species
Homo sapiens (Human)
Assay Type
Enrichment ImmunoMRM
Enrichment Method
peptide immunoaffinity
Matrix
plasma
Submitting Laboratory
Fred Hutchinson Cancer Research Center
Submitting Lab PI
Amanda Paulovich

Publication

View Details (opens in a new window)

Anti-peptide monoclonal antibodies generated for immuno-multiple reaction monitoring-mass spectrometry assays have a high probability of supporting Western blot and ELISA. Schoenherr RM, Saul RG, Whiteaker JR, Yan P, Whiteley GR, Paulovich AG. Mol Cell Proteomics. 2015 Feb;14(2):382-98. doi: 10.1074/mcp.O114.043133. Epub 2014 Dec 15. PMID: 25512614


Assay Parameters Collapse assay parameters

Data source: Panorama

Instrument
5500 Qtrap
Internal Standard
synthetic peptide
Peptide Standard Purity
>95%
Peptide Standard Label Type
13C and 15N at C-terminus K
LC
Eksigent NanoLC 2D
Column Packing
ReproSil-Pur C18-AQ 3 um
Column Dimensions
100 mm x 75 um ID
Flow Rate
300 nL/min

Chromatograms

Data source: Panorama


Response Curves

Data source: Panorama

Retrieving Data

Loader

Repeatability

Data source: Panorama

  Average intra-assay CV
(within day CV)
Average inter-assay CV
(between day CV)
Total CV
equation
n=
Fragment ion / Transition Low Med High Low Med High Low Med High Low Med High
b9 (1+) 20.8 3.5 3 32.4 4.6 5.8 38.5 5.8 6.5 15 15 15
y10 (2+) 22.3 4.2 3.7 36.5 5.7 5.9 42.8 7.1 7 15 15 15
y10 (1+) 16.6 2.9 3.2 19.7 8 6.3 25.8 8.5 7.1 15 15 15
sum 13.7 1.8 2.1 22.7 6.4 5.5 26.5 6.6 5.9 15 15 15


Additional Resources and Comments


Assay Details for CPTAC-3261 Collapse assay details

Data source: Panorama

Official Gene Symbol
UBE2I
Peptide Sequence
DHPFGFVAVPTK
Modification Type
unmodified
Protein - Site of Modification
N/A
Peptide - Site of Modification
N/A
Peptide Start
19
Peptide End
30
CPTAC ID
CPTAC-3261
Peptide Molecular Mass
1,313.6768
Species
Homo sapiens (Human)
Assay Type
Enrichment ImmunoMRM
Enrichment Method
peptide immunoaffinity
Matrix
cell lysate
Submitting Laboratory
Fred Hutchinson Cancer Research Center
Submitting Lab PI
Amanda Paulovich

Publication

View Details (opens in a new window)

A Multiplexed Mass Spectrometry-Based Assay for Robust Quantification of Phosphosignaling in Response to DNA Damage. Whiteaker JR, Zhao L, Saul R, Kaczmarczyk JA, Schoenherr RM, Moore HD, Jones-Weinert C, Ivey RG, Lin C, Hiltke T, Reding KW, Whiteley G, Wang P, Paulovich AG. Radiat Res. 2018 Feb 23. doi: 10.1667/RR14963.1. [Epub ahead of print]


Assay Parameters Collapse assay parameters

Data source: Panorama

Instrument
6500 QTRAP (Sciex)
Internal Standard
synthetic peptide
Peptide Standard Purity
>95%
Peptide Standard Label Type
13C and 15N at C-terminus K
LC
Ultra NanoLC 2D+ (Eksigent)
Column Packing
ReproSil-Pur C18-AQ 3um
Column Dimensions
100 x 0.075 mm
Flow Rate
300 uL/min

Chromatograms

Data source: Panorama


Response Curves

Data source: Panorama

Retrieving Data

Loader

Repeatability

Data source: Panorama

  Average intra-assay CV
(within day CV)
Average inter-assay CV
(between day CV)
Total CV
equation
n=
Fragment ion / Transition Low Med High Low Med High Low Med High Low Med High
y10 (1+) 13.3 8.2 8.1 31.1 10.9 7.8 33.8 13.6 11.2 15 15 15
b9 (1+) 21.3 7.1 10.6 37.1 12.2 14.1 42.8 14.1 17.6 15 15 15
y8 (1+) 17.7 15.8 14.1 49.4 32.2 14.4 52.5 35.9 20.2 15 15 15
sum 11.8 5.8 7.3 29.2 11.3 6.3 31.5 12.7 9.6 15 15 15


Additional Resources and Comments